  • Ultrasonic Partial Discharge Detector

    HTJF-9003 - Wuhan Huatian Electric Power Automation Co., Ltd.

    Used for on-line detection and localization of partial discharge in high voltage equipment.

  • Partial Discharge Measurement System

    DAC-6021 - Soken Electric Co. Ltd

    DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.

  • Partial Discharge Testing Equipment

    PD-Analyser - Scope T&M Pvt, Ltd.

    This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.

  • Partial Discharge and Tan Delta

    PDIX Series - High Voltage Inc.

    PDIX is a combined partial discharge and tan delta cable diagnostic testing system. By combining HVI’s VLF products with PDIX products, users can perform VLF AC withstand, partial discharge detection, and tan delta measurement on medium and high voltage cables, rotating machinery, and other apparatus with one integrated package fully supported by HVI & PDIX.

  • Partial Discharge Test Set

    NEO TELE-TRONIX PVT. LTD

    We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.

  • Partial Discharge Measurement Calibrator

    DAC-CP-2 - Soken Electric Co. Ltd

    DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).

  • Partial Discharge Measuring System

    PD - Shanghai Jiuzhi Electric Co., Ltd.

    Partial discharges (PD), as defined by IEC60270, are localized dielectric discharges in a partial area of a solid or liquid electrical dielectric insulation system under high-voltage field stress. It can be caused by discontinuities or imperfections in the insulation system. PD testing thus gives an indication of deterioration of the insulation and is an indicator of incipient faults. In general PD will occur in systems operating at voltages of 3000 V and above; it should be noted though that in some cases PD can also occur at lower voltages.

  • Partial Discharge Test System

    TPP - Mess- & Prüfsysteme GmbH

    The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).

  • Online Partial Discharge Monitor

    ASM-E - IPEC Ltd.

    The ASM-E is a permanent partial discharge monitor for cables, switchgear and other high voltage assets.The ASM-E can be configured with up to 128 PD sensor channels. If excessive discharge is detected, the ASM-E raises an alarm that can be configured either locally or by email/SMS. This enables the long-term assessment of plant conditions to be carried out quickly and easily, from any remote computer.

  • PD (Partial Discharge) Tester

    Weshine Electric Manufacturing Co., Ltd

    Using the Windows system operating platform, you can freely choose ellipse, straight line, sine wave display, two-dimensional, three-dimensional graphic analysis mode, spectrum window, Q-V-F three-dimensional characteristic window, and static detailed measurement, observation and analysis of partial discharge pulse of one-cycle test voltage .

  • Expert Partial Discharge Detector

    XDP-II™ - ndb Technologies Inc.

    The well-established XDP-II™ is a battery-operated portable device allowing partial discharge detection and analysis. The data is saved in its internal memory for local or further analysis on the PC-based XDP-SOFT™. Paired with the proper accessories, the XDP-II™ becomes a powerful solution for many applications such as Cable Joints and Elbows, Switchgear, Offline, Acoustic, TEV, Rotating machines, Transformer, etc…

  • Partial Discharge Measuring System

    LDS-6 - Doble Engineering

    The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis. It is trusted as a valuable tool for factory and laboratory testing.The LDS-6 can be used to test a variety of high voltage apparatus. Use the LDS-6 to perform PD quality tests on motors, generators, transformers, MV and HV cable systems, switchgear and additional HV accessories.The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • Partial Discharge Testing Equipment

    3i - Scope T&M Pvt, Ltd.

    The portable multipurpose 3i device (Intellectual Insulation Indicator) is for eff ective high-voltage equipment insulation monitoring on-line. The 3i device measures and analyses partial discharges (PD). For eff ective PD measurement and noise rejection, there are two types of sensors used in the device: the acoustic sensor and the TEV sensor. Both the sensors are built into the device case, and so do not need any connection cables. The device is supplied in a strong metal case; at the faceplate there are the colored screen and two buttons: power button and function button.

  • Partial Discharge Measuring System

    SG9101 - Shanghai Jiuzhi Electric Co., Ltd.

    Interference Distinguishing Partial Discharge (PD) Detector is a new type apparatus developed by the institute after SG-8001 (modeled from Model-5), SG-8201 and SG-8601 PD apparatuses. Basically it keeps the merits and functions of the above three types apparatuses. SG9101 adopts special interference distinguishing logical circuit, which can discriminates the accidental interference. (The interference must be high than a set threshold and last 4 test periods at least, the “effect” will be shown). Cooperating with the time window, it can enhance the ability to discriminate and eliminate external interference.